AirLink T3A Wireless Monitor
Dapatkan Penawaran
Detektor gas berbahaya di udara ambien AirLink T3A Series Gas Detector adalah rakitan serbaguna yang menggunakan elemen sensor manik-manik elektrokimia, inframerah, dan katalitik untuk mendeteksi berbagai macam gas. Daya kabel (12 hingga 35 VDC) dengan pengontrol komunikasi nirkabel. T3A nirkabel RKI juga memiliki output analog 4-20 mA dan RS-485 Modbus sebagai standar. Sakelar magnetik memungkinkan kalibrasi non-intrusif saat berada di lapangan serta pengaturan dan diagnostik sistem lengkap.
Airlink T3A mewakili teknologi terdepan terbaru dalam pendeteksian gas tetap saat ini.
Layanan Terkait
- Desain, Konsultasi, dan Rekayasa
- Instalasi
- Permulaan
- Pelatihan
- Pemeliharaan Sistem
Sensor Type | Electrochemical, infrared, catalytic bead | |
Operating Voltage | Wired power (3-Wire) 12 to 35 VDC | |
Power Draw | 2 Watts maximum | |
Protection | Power electromagnetic interference (EMI) filter
4-20 mA surge suppression RS-485 surge suppression | |
Display Screen | 102×64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight | |
Interface | 3 Push-buttons (MENU, ADD and SUB)
3 Magnetic non-intrusive switches for calibration | |
Customizable Settings | 2 Individual-configurable alarm LED/relay set-points | |
Temperature Range | -40°C to +60°C (-40°F to +140°F) | |
Wireless Output, Radio Options | 900 MHz (200 mW) radio (1-1.5 miles range) or 2.4 GHz (125 mW) radio (1-1.5 miles range) | |
Networks | 52 Networks (900 MHz radio) or 78 networks (2.4 GHz radio)
255 addresses per network | |
Output (digital) | RS-485 modbus | |
Wired (Analog) Output | 4-20 mA (3-Wire)
Fault terminal Optional 2 dry-contact relays with replaceable 4 amp fuses | |
Remote Sensor Kit
(Optional Additional Feature) | Remote sensor kit with enclosure (5 pin)
• Electrochemical sensor max. length: 250 feet • Infrared sensor max. length: 40 feet • Catalytic bead sensor max. length: 15 feet | |
Product Dimensions | 5.5 in, L x 6 in. D x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments) | |
Total Weight | 6 lbs. | |
Hazardous Location
Approvals | Main Enclosure | Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D Nema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G) Temp.= -20°C to +60°C |
Sensor Housing | Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D Temp.= -40°C to +60°C Note: Certification only applies to some gases. Toxic gases not certified for Div. 1 locations are suitable for Div. 2 applications but have no third party approval. | |
Controllers, Wireless | Compatible with AirLink 7010 and AirLink 7032 | |
Controllers, Analog | Compatible with all RKI Beacon controllers, as well as most DCS / PLC systems: Beacon 110, Beacon 200, Beacon 410A and Beacon 800, and MC-6400 | |
Warranty | 1-Year warranty for electronics and sensor |